Espressif Systems /ESP32-H2 /MCPWM0 /DT2_CFG

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as DT2_CFG

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0DB2_FED_UPMETHOD 0DB2_RED_UPMETHOD 0 (DB2_DEB_MODE)DB2_DEB_MODE 0 (DB2_A_OUTSWAP)DB2_A_OUTSWAP 0 (DB2_B_OUTSWAP)DB2_B_OUTSWAP 0 (DB2_RED_INSEL)DB2_RED_INSEL 0 (DB2_FED_INSEL)DB2_FED_INSEL 0 (DB2_RED_OUTINVERT)DB2_RED_OUTINVERT 0 (DB2_FED_OUTINVERT)DB2_FED_OUTINVERT 0 (DB2_A_OUTBYPASS)DB2_A_OUTBYPASS 0 (DB2_B_OUTBYPASS)DB2_B_OUTBYPASS 0 (DB2_CLK_SEL)DB2_CLK_SEL

Description

dead time type selection and configuration

Fields

DB2_FED_UPMETHOD

Update method for FED (falling edge delay) active register. 0: immediate,when bit0 is set to 1: tez, when bit1 is set to 1:tep, when bit2 is set to 1: sync, when bit3 is set to 1: disable the update

DB2_RED_UPMETHOD

Update method for RED (rising edge delay) active register. 0: immediate,when bit0 is set to 1: tez, when bit1 is set to 1:tep, when bit2 is set to 1: sync, when bit3 is set to 1: disable the update

DB2_DEB_MODE

S8 in table, dual-edge B mode, 0: fed/red take effect on different path separately, 1: fed/red take effect on B path, A out is in bypass or dulpB mode

DB2_A_OUTSWAP

S6 in table

DB2_B_OUTSWAP

S7 in table

DB2_RED_INSEL

S4 in table

DB2_FED_INSEL

S5 in table

DB2_RED_OUTINVERT

S2 in table

DB2_FED_OUTINVERT

S3 in table

DB2_A_OUTBYPASS

S1 in table

DB2_B_OUTBYPASS

S0 in table

DB2_CLK_SEL

Dead time generator 2 clock selection. 0: PWM_clk, 1: PT_clk

Links

() ()